Thermocouples, Temperature Probes

Results: 31.467
Stocking Options
Environmental Options
Media
Exclude
31.467Results

Showing
of 31.467
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Element Type
Temperature Range
Length - Lead Wire
Conductor Type
Terminal Type
DUAL SINGLE-WIRE TEMP SENSOR
DUAL SINGLE-WIRE TEMP SENSOR
SMSC
17.500
Marketplace
454 : 0,55718 €
Bulk
*
Bulk
Active
-
-
-
-
-
TEMPERATURE MONITOR
TEMPERATURE MONITOR
SMSC
275.000
Marketplace
142 : 1,78127 €
Bulk
*
Bulk
Active
-
-
-
-
-
LB11988V-TLM-E
ENVIRONMENTAL MONITORING AND CON
SMSC
2.500
Marketplace
111 : 2,27937 €
Bulk
*
Bulk
Active
-
-
-
-
-
MICROPOWER THERMOCOUPLE COLD JUN
MICROPOWER THERMOCOUPLE COLD JUN
Texas Instruments
383
Marketplace
51 : 5,01451 €
Bulk
*
Bulk
Active
-
-
-
-
-
P100-21040106
PT100, CL B, TCR .00385, M12, SS
Probes Unlimited, Inc.
26
Marketplace
1 : 47,92000 €
Bag
-
Bag
Active
Pt100
-40°C ~ 200°C
-
-
Connector
A-044802
gSKIN-XU-070501-X-CT, Heat-flux
greenteg AG
10.000
Marketplace
1 : 83,57000 €
Strip
Strip
Active
Thermopiles (N - Type and P - Type)
-50°C ~ 150°C
-
-
Exposed Terminals
A12-11-16-C
C, 1/4 X 10 AL2O3, UNG, SMC
Nanmac
89
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 10 AL2O3, UNG, SMC
Nanmac
65
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 10 AL2O3, UNG, SMC
Nanmac
94
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 10 AL2O3, UNG, SMC
Nanmac
59
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 12 AL2O3, UNG, SMC
Nanmac
82
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 12 AL2O3, UNG, SMC
Nanmac
98
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 12 AL2O3, UNG, SMC
Nanmac
77
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 12 AL2O3, UNG, SMC
Nanmac
70
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 14 AL2O3, UNG, SMC
Nanmac
63
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 14 AL2O3, UNG, SMC
Nanmac
63
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 14 AL2O3, UNG, SMC
Nanmac
72
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 14 AL2O3, UNG, SMC
Nanmac
58
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 16 AL2O3, UNG, SMC
Nanmac
83
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 16 AL2O3, UNG, SMC
Nanmac
94
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 16 AL2O3, UNG, SMC
Nanmac
88
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 16 AL2O3, UNG, SMC
Nanmac
51
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-18-C
C, 1/4 X 18 AL2O3, UNG, SMC
Nanmac
100
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 1/4 X 18 AL2O3, UNG, SMC
Nanmac
77
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
A12-11-16-C
C, 3/8 X 18 AL2O3, UNG, SMC
Nanmac
100
Marketplace
Unavailable
Unavailable in your selected currency
Box
Active
C - Type
300°C ~ 1750°C
-
Non-Grounded
Connector
Showing
of 31.467

What is a thermocouple?


A thermocouple is a rugged, reliable temperature sensor that converts a temperature difference directly into a measurable millivolt signal using the Seebeck effect. Made from two dissimilar metal wires joined at a sensing junction, thermocouples cover a broad range, from cryogenic temperatures below –200 °C up to noble metal types exceeding 1700 °C. For example, a Type K (nickel-chromium/nickel-alumel) is common in industrial furnaces, extrusion machines, and HVAC systems thanks to its wide range and durability. A Type J (iron-constantan) suits lower temperature ovens or kilns, while Types R and S (platinum-rhodium alloys) are chosen for extreme heat applications like glass production or aerospace engines.

A temperature probe, on the other hand, refers to the packaged form of a temperature sensor. A probe can house a thermocouple, RTD, or even a thermistor, mounted in a protective sheath with insulation and lead wires for practical use. In other words, a thermocouple is a sensing element, while a thermocouple probe is a ready-to-install assembly designed for a specific environment (e.g., food-safe stainless probes for dairy processing or Inconel-sheathed probes for turbines).

Like all sensors, thermocouples can fail. Key failure symptoms include:

Open circuit: No output signal due to a broken wire or corroded junction. Typically shows as an abnormally high or out-of-range reading.
Short circuit: Wires contact each other incorrectly, leading to unstable or inaccurate readings.
Drift: Gradual inaccuracy over time caused by oxidation, contamination, or mechanical stress, often critical in high-temperature industrial processes.
Noise or unstable signals: Can result from poor insulation, electromagnetic interference, or improper grounding.
Sluggish response: A sheath that has degraded or a partially damaged junction can cause delays in capturing real temperature changes.

Compared to RTDs, which excel in precision and stability but are more fragile, thermocouples are preferred where durability, wide temperature range, fast response, and lower cost matter most.